Title :
Alignment systems for the PHENIX muon tracking chambers
Author :
Brooks, M.L. ; Lee, D.M. ; Sondheim, W.
Author_Institution :
Los Alamos Nat. Lab., NM, USA
fDate :
6/1/1997 12:00:00 AM
Abstract :
The alignment systems required for the PHENIX muon tracking chamber system will be described. These systems include the system that has been developed to accurately electro-etch cathode strip foils with respect to external fiducial marks to a 25 μm accuracy, as well as the system that is being developed to measure the relative alignment of three stations of chambers spanning 4.5 meters, to an accuracy of 25 μm
Keywords :
muon detection; position measurement; position sensitive particle detectors; proportional counters; 25 mum; 4.5 m; PHENIX muon tracking chambers; alignment systems; autocollimation; cathode strip chambers; external fiducial marks; proportional counters; relative alignment; straightness monitors; Cathodes; Current measurement; Etching; Fasteners; Magnetic field measurement; Magnetic separation; Mesons; Optical feedback; Particle measurements; Strips;
Journal_Title :
Nuclear Science, IEEE Transactions on