• DocumentCode
    134655
  • Title

    Identifying root causes of failures in small electric motors

  • Author

    Purushothaman, S.

  • Author_Institution
    FM Global Res., Norwood, MA, USA
  • fYear
    2014
  • fDate
    27-31 July 2014
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    Accurate identification of root causes helps not only to prevent reoccurring failures but also the efficacy of the insurance claims settling process. Hence FM Global Research has undertaken a study to identify root causes of failures in small electric motors. The study involves a detailed literature review and the development of the Lightning-induced overvoltages (LIOV) matrix. This matrix was developed to evaluate the damage potential of individual indirect strikes by accounting for strike current magnitude and strike distance. This paper provides guidance to aid in identifying the root causes of motor failure under the categories: 1. Electrical insulation aging, 2. LIOV´s, or 3. Artificial surges.
  • Keywords
    electric motors; failure analysis; insulation; lightning; FM Global Research; LIOV matrix; artificial surges; electrical insulation aging; failures root causes identification; lightning-induced overvoltages matrix; motor failure; small electric motors; strike current magnitude; strike distance; Aging; Induction motors; Insulation; Lightning; Load modeling; Surge protection; Surges; Electric motors; indirect strikes; lightning; root cause analysis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    PES General Meeting | Conference & Exposition, 2014 IEEE
  • Conference_Location
    National Harbor, MD
  • Type

    conf

  • DOI
    10.1109/PESGM.2014.6938804
  • Filename