DocumentCode :
1352052
Title :
A fast hybrid system for PD measurement
Author :
Carminati, E. ; Gandelli, A. ; Lazzaroni, M.
Author_Institution :
Dipt. di Elettrotecnica, Politecnico di Milano, Italy
Volume :
7
Issue :
3
fYear :
2000
fDate :
6/1/2000 12:00:00 AM
Firstpage :
440
Lastpage :
445
Abstract :
A fast partial discharge (PD) measurement system is described, which employs analog as well as digital signal processing to achieve high sensitivity and discharge pulse resolution with low spectral distortion. Data on apparent charge, time of pulse occurrence and instantaneous applied voltage are stored in memory for subsequent information retrieval and treatment. The PD measurement system is designed to provide an integrated response to rapid rise time pulses of 1 to 2 ns, with suitable filtering added to reject extraneous noise.
Keywords :
partial discharge measurement; signal sampling; waveform analysis; 1 to 2 ns; PD measurement; analog signal processing; digital signal processing; discharge pulse resolution; extraneous noise; information retrieval; instantaneous applied voltage; integrated response; pulse occurrence; rise time pulses; sensitivity; spectral distortion; Digital signal processing; Distortion measurement; Information retrieval; Noise measurement; Partial discharge measurement; Partial discharges; Pulse measurements; Signal resolution; Time measurement; Voltage;
fLanguage :
English
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
1070-9878
Type :
jour
DOI :
10.1109/94.848934
Filename :
848934