• DocumentCode
    1366418
  • Title

    Analysis of Measurement Method for Critical Current Density by Using Permanent Magnet

  • Author

    Ikuno, Soichiro ; Takayama, Teruou ; Kamitani, Atsushi ; Takeishi, Kenta ; Saito, Atsushi ; Ohshima, Shigetoshi

  • Author_Institution
    Sch. of Comput. Sci., Tokyo Univ. of Technol., Hachioji, Japan
  • Volume
    19
  • Issue
    5
  • fYear
    2009
  • Firstpage
    3750
  • Lastpage
    3754
  • Abstract
    The permanent-magnet method for measuring critical current density in high-temperature superconducting thin films is numerically and experimentally investigated. Numerical results show that the critical current density is approximately proportional to the maximum repulsive force. Furthermore, the maximum repulsive force increases as the value of diameter of permanent magnet increases. This tendency is also observed in the experimental investigation. Finally, spatial distributions of the shielding current density are experimentally reproduced by the system.
  • Keywords
    critical current density (superconductivity); current distribution; electric current measurement; high-temperature superconductors; permanent magnets; superconducting thin films; critical current density; high-temperature superconducting thin films; maximum repulsive force; measurement method; permanent magnet; shielding current density spatial distributions; Critical current density; element-free Galerkin; high- $T_{c}$ superconductor;
  • fLanguage
    English
  • Journal_Title
    Applied Superconductivity, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1051-8223
  • Type

    jour

  • DOI
    10.1109/TASC.2009.2028297
  • Filename
    5235096