• DocumentCode
    1374182
  • Title

    A permeability analyzer for magnetic amplifier cores

  • Author

    Siskind, Philip

  • Author_Institution
    Sperry Gyroscope Company, Great Neck, N. Y.
  • Volume
    72
  • Issue
    5
  • fYear
    1953
  • Firstpage
    572
  • Lastpage
    576
  • Abstract
    This paper covers the theory and design of an instrument which measures, with the aid of an oscilloscope, the differential permeability of toroidal cores used in magnetic amplifiers. Additions and modifications are discussed which adapt the instrument for rapid selection of cores for production use, using a meter for an indicator. An important feature of the device is that all measurements are made before wire windings are placed on the cores.
  • Keywords
    Instruments; Magnetic cores; Magnetic flux; Magnetic hysteresis; Permeability; Toroidal magnetic fields; Windings;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
  • Publisher
    ieee
  • ISSN
    0097-2452
  • Type

    jour

  • DOI
    10.1109/TCE.1953.6371928
  • Filename
    6371928