DocumentCode :
1374871
Title :
Improvement and Metrological Validation of TDR Methods for the Estimation of Static Electrical Conductivity
Author :
Cataldo, Andrea ; Piuzzi, Emanuele ; Cannazza, Giuseppe ; De Benedetto, Egidio
Author_Institution :
Dept. of Eng. for Innovation, Univ. of Salento, Lecce, Italy
Volume :
59
Issue :
5
fYear :
2010
fDate :
5/1/2010 12:00:00 AM
Firstpage :
1207
Lastpage :
1215
Abstract :
Accurate measurement of the static electrical conductivity provides a great insight into the characteristics and quality status of various materials. To overcome some limitations of the traditional measurement methods, there has been a growing interest toward the investigation of enhanced techniques for measuring electrical conductivity. In this regard, time-domain reflectometry (TDR) has attracted considerable attention, also due to the possibility of simultaneously monitoring different physical parameters. Although initially introduced for monitoring soil properties, the application of the TDR-based technique might be an interesting and cost-effective means in many other fields. However, the accuracy of traditional TDR-based electrical conductivity measurements is strongly influenced by the preliminary calibration technique. On such basis, in this paper, two innovative approaches for a more straightforward and accurate evaluation of the electrical conductivity are presented. The first method relies on the combination of the TDR measurement with transmission-line modeling (TLM); the second method simply relies on a couple of independent capacitance measurements (ICMs) performed through an LCR meter. As a further goal, the metrological performance of this last method is compared with that of the traditional method, thus validating its applicability. Experimental results and related uncertainty analysis on various samples demonstrate that the proposed alternative method is definitely suitable for a simpler and accurate estimation of the static electrical conductivity, also when dealing with moistened soils.
Keywords :
capacitance measurement; capacitive sensors; electrical conductivity measurement; electrostatics; soil; time-domain reflectometry; transmission line theory; capacitance measurements; moistened soil; static electrical conductivity estimation; time domain reflectometry; transmission line modeling; Calibration; conductivity measurements; modeling; soil measurements; time-domain reflectometry (TDR);
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.2009.2038299
Filename :
5371989
Link To Document :
بازگشت