• DocumentCode
    1381850
  • Title

    H.F. Resistance Standards and their Use in the Calibration of an Admittance Bridge up to 60 Mc/s

  • Author

    Ward, W.H. ; Oliver, M.H. ; Fray, S.J.

  • Volume
    97
  • Issue
    50
  • fYear
    1950
  • fDate
    11/1/1950 12:00:00 AM
  • Firstpage
    438
  • Lastpage
    446
  • Abstract
    Transfer standards have been developed for calibrating, at frequencies from 200 kc/s to 60 Mc/s, an admittance bridge which measures 0¿100 millimhos and ¿150 ¿¿F to +150 ¿¿F. The standards have been used to give the bridge accuracies of about ± 2% ± 0.05 millimho in conductance, and between ± 0.2 ¿¿F and ± 4 ¿¿F in capacitance, depending on the conductance that is being measured at the same time. Suggestions are made for a new type of conductance standard that should make possible accuracies of better than ± 1 % in conductance, and better than ± 1 ¿¿F in capacitance.
  • Keywords
    bridge instruments; capacitance measurement; electric immittance;
  • fLanguage
    English
  • Journal_Title
    Proceedings of the IEE - Part III: Radio and Communication Engineering
  • Publisher
    iet
  • Type

    jour

  • DOI
    10.1049/pi-3.1950.0082
  • Filename
    5241148