• DocumentCode
    1385187
  • Title

    Improving Myoelectric Pattern Recognition Robustness to Electrode Shift by Changing Interelectrode Distance and Electrode Configuration

  • Author

    Young, Aaron J. ; Hargrove, Levi J. ; Kuiken, Todd A.

  • Author_Institution
    Center for Bionic Med., Rehabilitation Inst. of Chicago, Chicago, IL, USA
  • Volume
    59
  • Issue
    3
  • fYear
    2012
  • fDate
    3/1/2012 12:00:00 AM
  • Firstpage
    645
  • Lastpage
    652
  • Abstract
    Pattern recognition of myoelectric signals for prosthesis control has been extensively studied in research settings and is close to clinical implementation. These systems are capable of intuitively controlling the next generation of dexterous prosthetic hands. However, pattern recognition systems perform poorly in the presence of electrode shift, defined as movement of surface electrodes with respect to the underlying muscles. This paper focused on investigating the optimal interelectrode distance, channel configuration, and electromyography feature sets for myoelectric pattern recognition in the presence of electrode shift. Increasing interelectrode distance from 2 to 4 cm improved pattern recognition system performance in terms of classification error and controllability ( p <; 0.01). Additionally, for a constant number of channels, an electrode configuration that included electrodes oriented both longitudinally and perpendicularly with respect to muscle fibers improved robustness in the presence of electrode shift (p <; 0.05). We investigated the effect of the number of recording channels with and without electrode shift and found that four to six channels were sufficient for pattern recognition control. Finally, we investigated different feature sets for pattern recognition control using a linear discriminant analysis classifier and found that an autoregressive set significantly (p <; 0.01) reduced sensitivity to electrode shift compared to a traditional time-domain feature set.
  • Keywords
    biomedical electrodes; electromyography; medical signal processing; muscle; prosthetics; autoregressive set; distance 2 cm to 4 cm; electrode configuration; electrode shift; electromyography feature set; interelectrode distance; linear discriminant analysis classifier; muscle fiber; myoelectric pattern recognition robustness; myoelectric signal; pattern recognition control; prosthesis control; recording channel; Controllability; Electrodes; Electromyography; Materials; Muscles; Pattern recognition; Prosthetics; Electrode configuration; electrode shift; electromyography (EMG); pattern recognition; Arm; Artificial Limbs; Electrodes; Electromyography; Humans; Muscle Fibers, Skeletal; Pattern Recognition, Automated; Sensitivity and Specificity; Signal Processing, Computer-Assisted;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2011.2177662
  • Filename
    6092466