Title :
A novel approach to quantification of real and artifactual components of current density imaging for phantom and live heart
Author :
Foomany, F.H. ; Beheshti, M. ; Magtibay, K. ; Masse, S. ; Lai, P. ; Asta, J. ; Zamiri, N. ; Jaffray, D.A. ; Krishnan, Sridhar ; Nanthakumar, K. ; Umapathy, K.
Abstract :
Spatial distribution of injected current in a subject could be calculated and visualized through current density imaging (CDI). Calculated CDI paths however have a limited degree of accuracy due to both avoidable methodological errors and inevitable limitations dictated by MR imaging constraints. The source and impact of these limitations are scrutinized in this paper. Quantification of such limitations is an essential step prior to passing any judgment about the results especially in biomedical applications. An innovative technique along with metrics for evaluation of range of errors using baseline and phase cycle MR images is proposed in this work. The presented approach is helpful in pinpointing the local artifacts (areas for which CDI results are suspect), evaluation of global noises and artifacts and assessment of the effect of approximation algorithms on real and artifactual components. We will demonstrate how this error/reliability evaluation is applicable to interpretation of CDI results and in this framework, report the CDI results for an artificial phantom and a live pig heart in Langendorff setup. It is contended here that using this method, the inevitable trade-off between details and approximations of CDI components could be monitored which provides a great opportunity for robust interpretation of results. The proposed approach could be extended, adapted and used for statistical analysis of similar methods which aim at mapping current and impedance based on magnetic flux images obtained through MRI.
Keywords :
approximation theory; bioelectric potentials; biomedical MRI; cardiology; current density; electric impedance; error analysis; feature extraction; image reconstruction; medical image processing; noise; phantoms; reliability; statistical analysis; CDI component approximations; CDI component details; CDI path calculation accuracy; Langendorff setup; MR imaging constraint; approximation algorithm effect assessment; artifact evaluation; artifactual CDI component quantification; artificial phantom; baseline MR images; biomedical applications; current density imaging; current mapping; current spatial distribution calculation; current spatial distribution visualization; error range evaluation; error range metrics; error-reliability evaluation; global noise evaluation; impedance mapping; limitation quantification; live pig heart; local artifacts; magnetic flux images; methodological errors; phase cycle MR images; real CDI component quantification; statistical analysis; Current density; Fluctuations; Heart; Magnetic flux; Magnetic resonance imaging; Noise;
Conference_Titel :
Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE
Conference_Location :
Chicago, IL
DOI :
10.1109/EMBC.2014.6943780