DocumentCode :
139463
Title :
Interoperability of wearable cuffless BP measuring devices
Author :
Jing Liu ; Yuan-Ting Zhang
Author_Institution :
Dept. of Electron. Eng., Chinese Univ. of Hong Kong, Hong Kong, China
fYear :
2014
fDate :
26-30 Aug. 2014
Firstpage :
1374
Lastpage :
1377
Abstract :
While a traditional cuff-based Blood Pressure (BP) measuring device can only take a snap shot of BP, real-time and continuous measurement of BP without an occluding cuff is preferred which usually use the pulse transit time (PTT) in combination with other physiological parameters to estimate or track BP over a certain period of time after an initial calibration. This article discusses some perspectives of interoperability of wearable medical devices, based on IEEE P1708 draft standard that focuses on the objective performance evaluation of wearable cuffless BP measuring devices. The ISO/IEEE 11073 family of standards, supporting the plug-and play feature, is intended to enable medical devices to interconnect and interoperate with other medical devices and with computerized healthcare information systems in a manner suitable for the clinical environment. In this paper, the possible adoption of ISO/IEEE 11073 for the interoperability of wearable cuffless BP devices is proposed. In the consideration of the difference of the continuous and cuffless BP measuring methods from the conventional ones, the existing device specialization standards of ISO/IEEE 11073 cannot be directly followed when designing the cuffless BP device. Specifically, this paper discusses how the domain information model (DIM), in which vital sign information is abstracted as objects, is used to structure the information about the device and that generated from the device. Though attention should also be paid to adopt the communication standards for other parts for the communication system, applying communication standards that enable plug-and-play feature allows achieving the interoperability of different cuffless BP measuring devices with possible different configurations.
Keywords :
ISO standards; blood pressure measurement; body sensor networks; medical information systems; open systems; ISO-IEEE 11073 standards; communication system; computerized healthcare information systems; domain information model; interoperability; physiological parameters; plug-and-play feature; pulse transit time; vital sign information; wearable cuffless blood pressure measuring devices; wearable medical devices; Biomedical monitoring; Blood pressure; ISO standards; Interoperability; Medical diagnostic imaging;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE
Conference_Location :
Chicago, IL
ISSN :
1557-170X
Type :
conf
DOI :
10.1109/EMBC.2014.6943855
Filename :
6943855
Link To Document :
بازگشت