DocumentCode :
140697
Title :
Calibration of a 3D endoscopic system based on active stereo method for shape measurement of biological tissues and specimen
Author :
Furukawa, Ryo ; Aoyama, Masahito ; Hiura, Shinsaku ; Aoki, Hidetaka ; Kominami, Yoko ; Sanomura, Yoji ; Yoshida, Sigeru ; Tanaka, Shoji ; Sagawa, Ryusuke ; Kawasaki, Hiroshi
Author_Institution :
Fac. of Inf. Sci., Hiroshima City Univ., Hiroshima, Japan
fYear :
2014
fDate :
26-30 Aug. 2014
Firstpage :
4991
Lastpage :
4994
Abstract :
For endoscopic medical treatment, measuring the size and shape of the lesion, such as a tumor, is important for the improvement of diagnostic accuracy. We are developing a system to measure the shapes and sizes of living tissue by active stereo method using a normal endoscope on which a micro pattern projector is attached. In order to perform 3D reconstruction, estimating the intrinsic and extrinsic parameters of the endoscopic camera and the pattern projector is required. Particularly, calibration of the pattern projector is difficult. In this paper, we propose a simultaneous estimation method of both intrinsic and extrinsic parameters of the pattern projector. This simplifies the calibration procedure required in practical scenes. Furthermore, we have developed an efficient user interface to intuitively operate the calibration and reconstruction procedures. Using the developed system, we measured the shape of an internal tissue of the soft palate of a human and a biological specimen.
Keywords :
biomedical optical imaging; calibration; cameras; endoscopes; feature extraction; geometry; image reconstruction; medical control systems; medical image processing; optical projectors; parameter estimation; shape measurement; size measurement; stereo image processing; tumours; user interfaces; 3D endoscopic system calibration; 3D reconstruction; active stereo method; biological specimen shape measurement; diagnostic accuracy; endoscopic camera; endoscopic medical treatment; extrinsic parameter estimation; internal tissue shape measurement; intrinsic parameter estimation; intuitive calibration operation; intuitive reconstruction operation; lesion shape measurement; lesion size measurement; living tissue shape measurement; living tissue size measurement; micropattern projector; pattern projector calibration; pattern projector parameter estimation; simultaneous parameter estimation; soft palate tissue shape measurement; tumor shape measurement; tumor size measurement; user interface; Calibration; Cameras; Endoscopes; Image reconstruction; Lenses; Shape; Three-dimensional displays;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE
Conference_Location :
Chicago, IL
ISSN :
1557-170X
Type :
conf
DOI :
10.1109/EMBC.2014.6944745
Filename :
6944745
Link To Document :