• DocumentCode
    140729
  • Title

    The effect of acute coronary perfusion change on cardiac function measured by Shear Wave Elasticity Imaging

  • Author

    Vejdani-Jahromi, Maryam ; Kiplagat, Annette ; Trahey, Gregg E. ; Wolf, Patrick D.

  • Author_Institution
    Biomed. Eng. Dept., Duke Univ., Durham, NC, USA
  • fYear
    2014
  • fDate
    26-30 Aug. 2014
  • Firstpage
    5072
  • Lastpage
    5075
  • Abstract
    The possibility of measuring cardiac function noninvasively has generated wide interest in elastography imaging techniques. Shear Wave Elasticity Imaging (SWEI) is an ultrasound-based elastography technique used to measure stiffness of tissues. While this technique has been studied extensively in static homogenous tissues such as liver, breast or prostate, there is still a significant need to study its capabilities to measure cardiac stiffness and function. In this research, we have studied the potential of SWEI to evaluate the coronary perfusion pressure effect on systolic and diastolic stiffness referred to as elastance and compliance of the heart. Five isolated rabbit hearts were used in this study in a Langendorff preparation. SWEI measurements of stiffness were recorded in two steps. In the first step, coronary perfusion was set to normal and then was reduced to half-normal. After 40 minutes of half-normal perfusion, it was returned to normal perfusion for the second step. SWEI velocity decreased from 6.003 m/s to 4.713 m/s in systole and from 1.948 m/s to 1.507 m/s in diastole in the first step. During the second step raising the perfusion to normal, SWEI stiffness showed an increase from 3.760 m/s to 5.468 m/s in systole and from 1.678 m/s to 2.156 m/s during diastole. Our results show that SWEI measurements of stiffness can characterize the cross talk between coronary perfusion and cardiac stiffness and also has the potential to measure compliance and elastance of the heart in systole and diastole.
  • Keywords
    biological tissues; biomedical measurement; biomedical ultrasonics; cardiology; haemorheology; Langendorff preparation; SWEI; acute coronary perfusion change; cardiac function; cardiac stiffness; coronary perfusion pressure effect; diastolic stiffness; half-normal perfusion; heart compliance; heart elastance; rabbit hearts; shear wave elasticity imaging; systolic stiffness; tissue stiffness measurement; ultrasound-based elastography technique; Acoustics; Biomedical measurement; Cardiac tissue; Heart; Imaging; Ultrasonic imaging; Ultrasonic variables measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE
  • Conference_Location
    Chicago, IL
  • ISSN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/EMBC.2014.6944765
  • Filename
    6944765