DocumentCode :
1411960
Title :
Measurement of beam-loaded resonant frequency and quality factor in a gyroklystron input cavity using noise emissions
Author :
Calame, J.P. ; Garven, M. ; Danly, Bruce G.
Author_Institution :
Naval Res. Lab., Washington, DC, USA
Volume :
28
Issue :
3
fYear :
2000
fDate :
6/1/2000 12:00:00 AM
Firstpage :
638
Lastpage :
644
Abstract :
The spectral shape of noise emissions from a 35-GHz gyroklystron input cavity is used to directly measure the cavity resonant frequency and quality factor under beam-loaded conditions. The quality factors obtained with this technique at a number of magnetic fields are found to be consistent with quality factors obtained from reflection coefficient measurements made at the identical operating points. The measured variation in quality factor is used to identify various regimes of operation based on input cavity coupling. Comparisons between the measurements and simulations are in good agreement in resonant frequency, but moderate discrepancies in quality factor exist
Keywords :
Q-factor; digital simulation; gyrotrons; klystrons; 35 GHz; beam-loaded conditions; beam-loaded resonant frequency; cavity resonant frequency; gyroklystron input cavity; input cavity coupling; magnetic fields; noise emissions; operating points; quality factor measurement; quality factors; reflection coefficient measurements; spectral shape; Frequency measurement; Klystrons; Magnetic field measurement; Magnetic noise; Noise measurement; Noise shaping; Q factor; Resonant frequency; Shape measurement; Spectral shape;
fLanguage :
English
Journal_Title :
Plasma Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-3813
Type :
jour
DOI :
10.1109/27.887691
Filename :
887691
Link To Document :
بازگشت