DocumentCode :
1421683
Title :
Motorette tests: causes of variation in results
Author :
Appleby, J.T. ; Davies, C.L. ; Day, A.G. ; Douglas, G.C.G. ; Howard, C.P. ; Parriss, W.H.
Author_Institution :
Newman Industries Ltd., Bristol, UK
Volume :
117
Issue :
9
fYear :
1970
fDate :
9/1/1970 12:00:00 AM
Firstpage :
1777
Lastpage :
1781
Abstract :
Four laboratories have tested motorettes specially prepared by a fifth, using a similar procedure to that recommended in AIEE 510 (IEEE 117). Heat aging was at 200°C and a 2.3: 1 difference in measured life was obtained between laboratories. Consideration of possible variations in procedure and testing have failed to establish any specific causes for the differences in the results, and it is concluded that the recommended procedure could not give an estimated maximum working temperature within better than 16 deg C.
Keywords :
insulation testing; materials testing;
fLanguage :
English
Journal_Title :
Electrical Engineers, Proceedings of the Institution of
Publisher :
iet
ISSN :
0020-3270
Type :
jour
DOI :
10.1049/piee.1970.0317
Filename :
5249285
Link To Document :