Assessment of MODIS Thermal Emissive Band On-Orbit Calibration
Author
Chang, Tiejun ; Xiong, Xiaoxiong
Author_Institution
Sigma Space Corp., Lanham, MD, USA
Volume
49
Issue
6
fYear
2011
fDate
6/1/2011 12:00:00 AM
Firstpage
2415
Lastpage
2425
Abstract
Sixteen Moderate Resolution Imaging Spectroradiometer thermal emissive bands (TEBs) cover the wavelength from 3.75 to 14.24 μm. TEB calibration uses data collected from the detector responses to the onboard blackbody (BB) and space view. The BB was designed to operate either at a constant temperature for detector linear gain calibration or at temperatures varying from ambient (~270 K) to 315 K for on-orbit characterization of nonlinear coefficients. In this paper, we assess TEB on-orbit calibration performance in two aspects: One is to review the calibration trending on the orbital, daily, and multiyear timescales, and the other is to analyze the on-orbit calibration radiance uncertainty and its impact on the calibration. The calibration trending confirms the detector response dependence on the instrument temperature. The temperature trending and prelaunch characterization provide the basis for determining the calibration radiance source temperature range and uncertainties. An analytical approach was used to assess the impacts of onboard radiance uncertainties. The BB emission uncertainty, resulting from the temperature measurement error and emissivity uncertainty, causes a calibration uncertainty up to 0.3%, a value decreasing with the band wavelength. The BB nonblackness effect is analyzed and found to be insignificant. For the band with the lowest BB emissivity, the nonblackness affects the calibration radiance by less than 0.08%. The cavity emission uncertainty and the scan-mirror emission uncertainty both cause a less than 0.1% calibration uncertainty. The analysis of the nonlinear calibration coefficient uncertainty shows that its effect on the low Earth-view brightness-temperature range varies by band and is generally insignificant.
Keywords
atmospheric measuring apparatus; blackbody radiation; calibration; emissivity; radiometers; remote sensing; MODIS thermal emissive band on-orbit calibration; Moderate Resolution Imaging Spectroradiometer; TEB on-orbit calibration; blackbody emission uncertainty; detector linear gain calibration; emissivity uncertainty; low Earth-view brightness temperature range; onboard blackbody; radiance uncertainty; space view; temperature measurement error; temperature trending; thermal emissive band calibration; Calibration; Cavity resonators; Detectors; MODIS; Temperature measurement; Uncertainty; Blackbody (BB); Moderate Resolution Imaging Spectroradiometer (MODIS); onboard calibration; thermal emissive bands (TEBs);
fLanguage
English
Journal_Title
Geoscience and Remote Sensing, IEEE Transactions on
Publisher
ieee
ISSN
0196-2892
Type
jour
DOI
10.1109/TGRS.2010.2098881
Filename
5696752
Link To Document