Title :
Pulling loads on single- and multiple-conductor impregnated-paper lead-encased cable, solid type
Author :
Bellis, A. P. S.
Author_Institution :
John A. Roebling´s Sons Co., Trenton, N. J.
fDate :
3/1/1943 12:00:00 AM
Abstract :
LACK of factual information relative to the permissible pulling loads to which solid-type impregnated-paper lead-sheath power cable might be subjected by means of woven-wire pulling grips without damage to the sheath prompted the Insulated Power Cable Engineers Association to consider the subject and resulted in the laboratory tests described in this paper.
Keywords :
Cable insulation; Cable shielding; Conductors; Oil filled cables; Power cables; Strain;
Journal_Title :
Electrical Engineering
DOI :
10.1109/EE.1943.6435654