Abstract :
A detailed model of the R-L-fed inverting substation, for use of power flow and harmonic studies in DC electrified transit systems, has been presented in this paper. A unified Newton-Raphson method is adopted as the solution approach of the AC/DC power flows. The harmonic study is performed by the Y-bus method using the derived harmonic current injections of the converter. The Chungho Line of Taipei Rapid Transit Systems is given as a numerical example system. Effects of the application of inverting substations to the example system are investigated. The detailed converter model and the fast power flow algorithm can be easily applied to train simulators to complete a more accurate and rapid electric network solution of transit systems
Keywords :
Newton-Raphson method; invertors; load flow; power conversion harmonics; railways; rapid transit systems; substations; AC/DC power flows; Chungho Line; DC electrified transit systems; DC transit systems; R-L-fed inverting substation; Taipei Rapid Transit Systems; Y-bus method; converter model; electric network solutions; fast power flow algorithm; harmonic current injections; harmonics; inverting substations; power flow; train simulators; unified Newton-Raphson method; Electric resistance; Inverters; Load flow; Power system harmonics; Power system modeling; Rail transportation; Reactive power; Rectifiers; Substations; Voltage;
fLanguage :
English
Journal_Title :
Vehicular Technology, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9545
Type :
jour
DOI :
10.1109/25.728537
Filename :
728537
Link To Document :
بازگشت