DocumentCode
1454881
Title
Interlaminar insulation test for stators
Author
Tomlinson, H. R.
Author_Institution
New England Power Service Company, Boston, Mass.
Volume
71
Issue
11
fYear
1952
Firstpage
1024
Lastpage
1024
Abstract
IT IS OFTEN DESIRABLE to test the effectiveness of the interlaminar insulation in a generator stator. Iron damage may be sustained as a consequence of mechanical abrasion or arc burning during a winding insulation failure. A simple flux test can be made to determine if the interlaminar insulation has been impaired within a damaged area which might develop into a hot spot when the machine is restored to service.
Keywords
Coils; Insulation; Iron; Magnetic flux; Saturation magnetization; Stators; Windings;
fLanguage
English
Journal_Title
Electrical Engineering
Publisher
ieee
ISSN
0095-9197
Type
jour
DOI
10.1109/EE.1952.6437791
Filename
6437791