DocumentCode :
1457133
Title :
Depth of anesthesia estimation and control [using auditory evoked potentials]
Author :
Huang, Johnnie W. ; Lu, Ying-Ying ; Nayak, Abinash ; Roy, Rob J.
Author_Institution :
Dept. of Biomed. Eng., Rensselaer Polytech. Inst., Troy, NY, USA
Volume :
46
Issue :
1
fYear :
1999
Firstpage :
71
Lastpage :
81
Abstract :
A fully automated system was developed for the depth of anesthesia estimation and control with the intravenous anesthetic, Propofol. The system determines the anesthesia depth by assessing the characteristics of the mid-latency auditory evoked potentials (MLAEP). The discrete time wavelet transformation was used for compacting the MLAEP which localizes the time and the frequency of the waveform. Feature reduction utilizing step discriminant analysis selected those wavelet coefficients which best distinguish the waveforms of those responders from the nonresponders. A total of four features chosen by such analysis coupled with the Propofol effect-site concentration were used to train a four-layer artificial neural network for classifying between the responders and the nonresponders. The Propofol is delivered by a mechanical syringe infusion pump controlled by Stanpump which also estimates the Propofol effect-site and plasma concentrations using a three-compartment pharmacokinetic model with the Tackley parameter set. In the animal experiments on dogs, the system achieved a 89.2% accuracy rate for classifying anesthesia depth. This result was further improved when running in real-time with a confidence level estimator which evaluates the reliability of each neural network output. The anesthesia level is adjusted by scheduled incrementation and a fuzzy-logic based controller which assesses the mean arterial pressure and/or the heart rate for decrementation as necessary. Various safety mechanisms are implemented to safeguard the patient from erratic controller actions caused by external disturbances. This system completed with a friendly interface has shown satisfactory performance in estimating and controlling the depth of anesthesia.
Keywords :
auditory evoked potentials; biocontrol; discrete wavelet transforms; medical signal processing; neural nets; surgery; Propofol effect-site; Stanpump; Tackley parameter set; anesthesia depth control; anesthesia depth estimation; animal experiments; discrete time wavelet transformation; dogs; four-layer artificial neural network; fuzzy-logic based controller; heart rate; intravenous anesthetic; mean arterial pressure; mechanical syringe infusion pump; midlatency auditory evoked potentials characteristics assessment; nonresponders; plasma concentrations; responders; step discriminant analysis; three-compartment pharmacokinetic model; wavelet coefficients; Anesthesia; Anesthetic drugs; Animals; Artificial neural networks; Automatic control; Control systems; Discrete wavelet transforms; Frequency; Plasmas; Wavelet coefficients; Algorithms; Anesthesia, General; Anesthetics, Intravenous; Animals; Discriminant Analysis; Dogs; Evoked Potentials, Auditory; Fuzzy Logic; Hemodynamics; Infusion Pumps; Neural Networks (Computer); Propofol; ROC Curve; Signal Processing, Computer-Assisted; Wakefulness;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/10.736759
Filename :
736759
Link To Document :
بازگشت