DocumentCode
1462271
Title
Total dose test of commercial off-the-shelf components to be used in power supply for space experiments
Author
Menichelli, M. ; Battiston, R. ; Bizzaglia, S. ; Blasko, S. ; Castellini, G. ; Di Masso, L. ; Gabbanini, A. ; Papi, A. ; Scolieri, G. ; Tesi, M.
Author_Institution
Dept. of Phys., Ist. Nazionale di Fisica Nucl., Perugia, Italy
Volume
47
Issue
6
fYear
2000
fDate
12/1/2000 12:00:00 AM
Firstpage
1879
Lastpage
1884
Abstract
Commercial off-the-shelf components have been tested for their use on the power supplies of the AMS and PAMELA experiments. The test has been performed using the CALLIOPE Co60 source at the Casaccia (Rome-Italy) Laboratory of ENEA according to the ESA/SCC 22900 specifications. The total dose for this test was 30 krads. Measurements of relevant parameters for each component has been taken at 3, 10 and 30 krads. Annealing and ageing has also been performed according to the ESA specification. The results on the degradation of performances in discrete transistors, Op-Amps, regulators and other analog and digital components are reported
Keywords
annealing; cosmic ray apparatus; dosimetry; space vehicle power plants; 10 krad; 3 krad; 30 krad; AMS experiment; CALLIOPE 60Co source; ESA/SCC 22900 specifications; PAMELA experiment; ageing; annealing; commercial off-the-shelf components; discrete transistors; power supply; space experiments; total dose test; Aging; Annealing; Circuit testing; Laboratories; Operational amplifiers; Performance evaluation; Power supplies; Regulators; Space stations; Temperature;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/23.914463