DocumentCode :
1462328
Title :
Precision AC–DC Difference Measurement System Based on a Programmable Josephson Voltage Standard
Author :
Budovsky, Ilya ; Georgakopoulos, Dimitrios ; Hagen, Thomas ; Sasaki, Hitoshi ; Yamamori, Hirotake
Author_Institution :
Nat. Meas. Inst., Lindfield, NSW, Australia
Volume :
60
Issue :
7
fYear :
2011
fDate :
7/1/2011 12:00:00 AM
Firstpage :
2439
Lastpage :
2444
Abstract :
A system designed for precision measurement of ac-dc difference of thermal voltage converters in terms of a programmable Josephson voltage standard is under development at the National Measurement Institute, Australia, in collaboration with the National Institute of Advanced Industrial Science and Technology, Japan. The agreement between the new system and calculable thermal converters is presently better than 0.5 μV/V at frequencies up to 40 Hz and voltages up to 0.75 V.
Keywords :
AC-DC power convertors; Josephson effect; programmable circuits; voltage measurement; IEEE thermal voltage converters; National Institute of Advanced Industrial Science and Technology; National Measurement Institute; frequency 40 Hz; precision AC-DC difference measurement system; programmable Josephson voltage standard; voltage 0.75 V; Current measurement; Radio frequency; Standards; Switches; Transient analysis; Uncertainty; Voltage measurement; Alternating-current–direct-current (ac–dc) transfer standards; Josephson arrays; Josephson devices; alternating voltage measurement;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.2011.2108554
Filename :
5722030
Link To Document :
بازگشت