Title :
Measurement of stray-load loss in induction motors
Author_Institution :
General Electric Company, Schenectady, N. Y.
fDate :
4/1/1945 12:00:00 AM
Abstract :
This paper is written to present test data confirming the accuracy of the reverse-rotation test for stray-load loss24 in polyphase induction motors. This method is the most convenient yet proposed for direct measurement of stray-load losses in squirrel-cage motors, and it is recommended that it be included in the AIEE Test Code for Polyphase Induction Machines.27 Proposals for this revision are made.
Keywords :
Current measurement; Induction motors; Loss measurement; Rotors; Stator cores; Stator windings;
Journal_Title :
Electrical Engineering
DOI :