DocumentCode
1474610
Title
Transient response of controlled rectifier circuits
Author
Chin, P. T. ; Walter, G. E.
Author_Institution
General Electric Company Schenectady, N. Y.
Volume
64
Issue
4
fYear
1945
fDate
4/1/1945 12:00:00 AM
Firstpage
208
Lastpage
214
Abstract
Transients in circuits supplied by controlled rectifiers using gas or mercury-vapor-filled electron tubes are found analytically by an extended superposition method. Loads containing resistance, inductance, and a counter electromotive force are studied, and results are obtained for both rectification and inversion. Examples are based on the half-wave biphase rectifier, while the appendix contains an analysis of a p-phase rectifier. The assumptions include constant-circuit parameters, a fixed firing angle during transients, continuous load current, and no-leakage reactance in the supply transformer.
Keywords
Electron tubes; Firing; Force; Inductance; Radiation detectors; Rectifiers; Transient analysis;
fLanguage
English
Journal_Title
Electrical Engineering
Publisher
ieee
ISSN
0095-9197
Type
jour
DOI
10.1109/EE.1945.6440977
Filename
6440977
Link To Document