• DocumentCode
    1479916
  • Title

    Sensing methods for a 3-phase load transfer contactor

  • Author

    Epstein, P. L. ; Stineman, R. W.

  • Author_Institution
    Boeing Airplane Company, Seattle, Wash.
  • Volume
    75
  • Issue
    4
  • fYear
    1956
  • fDate
    4/1/1956 12:00:00 AM
  • Firstpage
    336
  • Lastpage
    336
  • Abstract
    A LOAD TRANSFER CONTACTOR is a device which connects a bank of loads to one of two power sources, herein called the normal and alternate power sources. Self-contained load transfer contactors presently employed in aircraft contain three sensing relays, each relay being connected line-to-neutral, to detect failure of the normal power source. This arrangement has the disadvantages that line-to-line faults on the normal power source may not be detected, required close tolerances on pickup and dropout voltage are difficult to maintain in an aircraft environment, and loads may be unnecessarily transferred to an alternate power source.
  • Keywords
    Aircraft; Circuit faults; Companies; Industries; Relays; Temperature sensors;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineering
  • Publisher
    ieee
  • ISSN
    0095-9197
  • Type

    jour

  • DOI
    10.1109/EE.1956.6441835
  • Filename
    6441835