DocumentCode :
1481496
Title :
Ultrasonic viscosity measurement using the shear-wave reflection coefficient with a novel signal processing technique
Author :
Franco, Ediguer E. ; Adamowski, Julio C. ; Buiochi, Flávio
Author_Institution :
Sch. of Eng., Univ. of Sao Paulo, Sao Paulo, Brazil
Volume :
57
Issue :
5
fYear :
2010
fDate :
5/1/2010 12:00:00 AM
Firstpage :
1133
Lastpage :
1139
Abstract :
Real-time viscosity measurement remains a necessity for highly automated industry. To resolve this problem, many studies have been carried out using an ultrasonic shear wave reflectance method. This method is based on the determination of the complex reflection coefficient´s magnitude and phase at the solid-liquid interface. Although magnitude is a stable quantity and its measurement is relatively simple and precise, phase measurement is a difficult task because of strong temperature dependence. A simplified method that uses only the magnitude of the reflection coefficient and that is valid under the Newtonian regimen has been proposed by some authors, but the obtained viscosity values do not match conventional viscometry measurements. In this work, a mode conversion measurement cell was used to measure glycerin viscosity as a function of temperature (15 to 25??C) and corn syrup-water mixtures as a function of concentration (70 to 100 wt% of corn syrup). Tests were carried out at 1 MHz. A novel signal processing technique that calculates the reflection coefficient magnitude in a frequency band, instead of a single frequency, was studied. The effects of the bandwidth on magnitude and viscosity were analyzed and the results were compared with the values predicted by the Newtonian liquid model. The frequency band technique improved the magnitude results. The obtained viscosity values came close to those measured by the rotational viscometer with percentage errors up to 14%, whereas errors up to 96% were found for the single frequency method.
Keywords :
acoustic signal processing; elastic waves; organic compounds; phase measurement; ultrasonic measurement; viscometers; viscosity; viscosity measurement; Newtonian liquid model; bandwidth effects; complex reflection coefficient; corn syrup-water mixtures; frequency 1 MHz; frequency band technique; glycerin viscosity; mode conversion measurement cell; phase measurement; real-time viscosity measurement; rotational viscometer; shear-wave reflection coefficient; signal processing technique; solid-liquid interface; temperature 15 degC to 25 degC; ultrasonic shear wave reflectance method; ultrasonic viscosity measurement; viscometry measurements; Frequency; Phase measurement; Reflection; Reflectivity; Signal processing; Signal resolution; Temperature dependence; Testing; Ultrasonic variables measurement; Viscosity;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/TUFFC.2010.1524
Filename :
5456261
Link To Document :
بازگشت