Title :
Determination of stray load loss in D-C machines
Author :
Sieron, R. L. ; Grant, D. A.
Author_Institution :
Connecticut Light & Power Company, Hartford, Conn.
Abstract :
A SPECIALLY DEVISED METHOD using the Blondel load-back principle of loss measurement has been employed to measure the stray load loss in d-c machines. An inherently accurate value of the loss is obtained by measuring it as two separate components by a method which is direct and easy to perform.
Keywords :
Associate members; Current measurement; Generators; Loss measurement; Resistance; Shafts; Temperature measurement;
Journal_Title :
Electrical Engineering
DOI :
10.1109/EE.1957.6442980