    A fast minimum variance beamforming method using principal component analysis

  • Author

    Kyuhong Kim ; Suhyun Park ; Jungho Kim ; Sung-Bae Park ; MooHo Bae

  • Author_Institution
    Samsung Adv. Inst. of Technol., Samsung Electron., Yongin, South Korea
  • Volume
    61
  • Issue
    6
  • fYear
    2014
  • fDate
    Jun-14
  • Firstpage
    930
  • Lastpage
    945
  • Abstract
    Minimum variance (MV) beamforming has been studied for improving the performance of a diagnostic ultrasound imaging system. However, it is not easy for the MV beamforming to be implemented in a real-time ultrasound imaging system because of the enormous amount of computation time associated with the covariance matrix inversion. In this paper, to address this problem, we propose a new fast MV beamforming method that almost optimally approximates the MV beamforming while reducing the computational complexity greatly through dimensionality reduction using principal component analysis (PCA). The principal components are estimated offline from pre-calculated conventional MV weights. Thus, the proposed method does not directly calculate the MV weights but approximates them by a linear combination of a few selected dominant principal components. The combinational weights are calculated in almost the same way as in MV beamforming, but in the transformed domain of beamformer input signal by the PCA, where the dimension of the transformed covariance matrix is identical to the number of some selected principal component vectors. Both computer simulation and experiment were carried out to verify the effectiveness of the proposed method with echo signals from simulation as well as phantom and in vivo experiments. It is confirmed that our method can reduce the dimension of the covariance matrix down to as low as 2 × 2 while maintaining the good image quality of MV beamforming.
  • Keywords
    array signal processing; biomedical ultrasonics; covariance matrices; medical image processing; phantoms; principal component analysis; MV beamforming method; beamformer input signal; covariance matrix inversion; diagnostic ultrasound imaging system; echo signals; fast minimum variance beamforming method; image quality; phantom; pre-calculated conventional MV weights; principal component analysis; real-time ultrasound imaging system; transformed covariance matrix; transformed domain; Array signal processing; Computational complexity; Covariance matrices; Phantoms; Principal component analysis; Vectors;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2014.2989
  • Filename
    6819209