Title :
X-ray thickness gauge for cold rolled strip steel
Author_Institution :
X-ray division of the Westinghouse Electric Corporation, Baltimore, Md.
fDate :
4/1/1948 12:00:00 AM
Abstract :
Design has been completed of an X-ray thickness gauge for cold mill and other applications utilizing one photoelectric multiplier pickup and two X-ray sources. The range of the gauge is 5 to 50 thousandths of an inch with accuracies up to one per cent.
Keywords :
Electron tubes; Fluorescence; Instruments; Materials; Standards; Steel;
Journal_Title :
Electrical Engineering
DOI :
10.1109/EE.1948.6444059