DocumentCode
1521553
Title
Experiments with thermocouple milliammeters at very high radio frequencies
Author
Gainsborough, G.F.
Volume
91
Issue
15
fYear
1944
fDate
9/1/1944 12:00:00 AM
Firstpage
156
Lastpage
161
Abstract
A description is given of the calibration of commercial thermocouple milliammeters at frequencies of 100 Mc/s and 700 Mc/s. Errors dependent on current amplitude were found, and were shown to be due to the magnetic properties of the material used for the heater wires. The occurrence is confirmed of frequency-dependent errors, due to the method of constructing the ordinary instruments. Specially made instruments, though superior in respect of these errors, are likely to be of limited usefulness on account of the disturbance which is caused by the inclusion of any such device in a circuit carrying current at very high frequencies.
Keywords
ammeters; thermoelectricity;
fLanguage
English
Journal_Title
Electrical Engineers - Part III: Communication Engineering, including the Proceedings of the Wireless Section of the Institution, Journal of the Institution of
Publisher
iet
Type
jour
DOI
10.1049/ji-3-1.1944.0032
Filename
5298330
Link To Document