DocumentCode
153173
Title
THz autocorrelation measurements at the Metrology Light Source
Author
Pohl, A. ; Desmann, N. ; Hoehl, A. ; Muller, Rudolf ; Ulm, G. ; Ries, M. ; Wustefeld, G. ; Hubers, Heinz-Wilhelm
Author_Institution
Inst. fur Opt. und atomare Phys., Tech. Univ. Berlin, Berlin, Germany
fYear
2014
fDate
14-19 Sept. 2014
Firstpage
1
Lastpage
2
Abstract
We have developed a flexible Martin-Puplett Interferometer setup utilizing broad band coherent terahertz (THz) synchrotron radiation provided by the Metrology Light Source (MLS). In order to obtain frequency resolved measurements we combined the Martin-Puplett setup with a Fourier transform spectrometer (FTS). Frequency resolved autocorrelation measurements for beam diagnostics will be presented.
Keywords
Fourier transform spectrometers; light interferometers; terahertz wave detectors; Fourier transform spectrometer; Metrology Light Source; THz autocorrelation measurements; broad band coherent terahertz synchrotron radiation; flexible Martin-Puplett Interferometer setup; frequency resolved measurements; Correlation; Frequency measurement; Light sources; Metrology; Optical interferometry; Signal resolution; Storage rings;
fLanguage
English
Publisher
ieee
Conference_Titel
Infrared, Millimeter, and Terahertz waves (IRMMW-THz), 2014 39th International Conference on
Conference_Location
Tucson, AZ
Type
conf
DOI
10.1109/IRMMW-THz.2014.6956300
Filename
6956300
Link To Document