DocumentCode :
1540501
Title :
Testing of large aperture superferric quadrupoles
Author :
Zeller, A.F. ; Zink, R. ; Wagner, J. ; Hitchcock, S. ; DeKamp, J.C. ; Balint, A.
Author_Institution :
Nat. Supercond. Cyclotron Lab., Michigan State Univ., East Lansing, MI, USA
Volume :
9
Issue :
2
fYear :
1999
fDate :
6/1/1999 12:00:00 AM
Firstpage :
693
Lastpage :
696
Abstract :
Five different types of superferric quadrupoles are being built for the A1900 Fragment Separator at the NSCL. At least one of each type has been built and tested in an open helium vessel. Quench behavior was recorded and analyzed. Results were compared to calculated quantities such as internal voltages. The measured internal voltages were always less than those calculated with any set of reasonable parameters. All magnets exhibited some training, but every one met or exceeded the required maximum gradients.
Keywords :
accelerator magnets; cyclotrons; superconducting magnets; A1900 Fragment Separator; NSCL; National Superconducting Cyclotron Lab; internal voltages measurement; large aperture superferric quadrupoles testing; magnet training; open helium vessel; quench behavior; Apertures; Circuit testing; Coils; Cyclotrons; Iron; Magnetic circuits; Particle separators; Superconducting magnets; Voltage;
fLanguage :
English
Journal_Title :
Applied Superconductivity, IEEE Transactions on
Publisher :
ieee
ISSN :
1051-8223
Type :
jour
DOI :
10.1109/77.783390
Filename :
783390
Link To Document :
بازگشت