• DocumentCode
    1550145
  • Title

    Effect of dead time on harmonic distortion in class-D audio power amplifiers

  • Author

    Mosely, I.D. ; Mellor, P.H. ; Bingham, C.M.

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Machines & Drives Group, Sheffield, UK
  • Volume
    35
  • Issue
    12
  • fYear
    1999
  • fDate
    6/10/1999 12:00:00 AM
  • Firstpage
    950
  • Lastpage
    952
  • Abstract
    A model is described for predicting the harmonic levels introduced by the use of dead time in class-D, PWM-driven audio power output stages. The model demonstrates that the harmonic levels are a function of load impedance, modulation depth, dead time and switching frequency. In addition, measurements show that, for audio applications, dead time is the dominant cause of power stage nonlinearity
  • Keywords
    audio-frequency amplifiers; harmonic distortion; power amplifiers; pulse width modulation; PWM-driven audio power output stages; class-D audio power amplifiers; dead time; harmonic distortion; load impedance; modulation depth; power stage nonlinearity; switching frequency;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19990705
  • Filename
    788036