DocumentCode :
1552236
Title :
Nonovershooting and monotone nondecreasing step responses of a third-order SISO linear system
Author :
Lin, Shir-Kuan ; Fang, Chang-Jia
Author_Institution :
Dept. of Control Eng., Nat. Chiao Tung Univ., Hsinchu, Taiwan
Volume :
42
Issue :
9
fYear :
1997
fDate :
9/1/1997 12:00:00 AM
Firstpage :
1299
Lastpage :
1303
Abstract :
This paper presents the necessary and sufficient conditions for a third-order single-input/single-output (SISO) linear system to have a nonovershooting (or monotone nondecreasing) step response. If the transfer function of an overall system has real poles, a necessary and sufficient condition is found for the nonovershooting (or monotone nondecreasing) step response. In the case of complex poles, one sufficient condition and two necessary conditions are obtained. The resulting conditions are all in terms of the coefficients of the numerator of the transfer function. Simple calculations can be used to check a system for the nonovershooting (or monotone nondecreasing) step response. Another feature is that the conditions in terms of pole-zero configurations can be easily derived from the present results
Keywords :
control system analysis; linear systems; poles and zeros; step response; three-term control; transfer functions; transient response; PID controller; SISO system; complex poles; monotone nondecreasing step responses; necessary conditions; nonovershooting step response; sufficient conditions; third-order linear system; transfer function; Automatic control; Bandwidth; Communication system control; Control systems; Linear systems; Motion control; Proportional control; State estimation; Sufficient conditions; Transfer functions;
fLanguage :
English
Journal_Title :
Automatic Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9286
Type :
jour
DOI :
10.1109/9.623097
Filename :
623097
Link To Document :
بازگشت