• DocumentCode
    157017
  • Title

    Calorimetric and input-output loss determination of SynRM

  • Author

    Aarniovuori, L. ; Kolehmainen, J. ; Kosonen, A. ; Niemela, M. ; Pyrhonen, Juha

  • Author_Institution
    Dept. of Electr. Eng., Lappeenranta Univ. of Technol., Lappeenranta, Finland
  • fYear
    2014
  • fDate
    2-5 Sept. 2014
  • Firstpage
    79
  • Lastpage
    85
  • Abstract
    90 kW frequency converter driven synchronous reluctance machine losses are determined simultaneously with the input-output powers and with the calorimetric method. Uncertainty of both measurement methods is analyzed and discussed. Calorimetric measurement system that is capable to determine the losses of the motor frame size up to 315 is introduced.
  • Keywords
    calorimetry; frequency convertors; loss measurement; reluctance motors; calorimetric loss measurement system; frequency converter; input-output power loss; motor frame size; power 90 kW; synRM; synchronous reluctance machine losses; Current measurement; Frequency measurement; Heating; Loss measurement; Power measurement; Temperature measurement; Uncertainty; Synchronous reluctance motor; calorimeter; measurement; pulse-width-modulation; variable speed drives;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines (ICEM), 2014 International Conference on
  • Conference_Location
    Berlin
  • Type

    conf

  • DOI
    10.1109/ICELMACH.2014.6960162
  • Filename
    6960162