• DocumentCode
    157304
  • Title

    Advanced condition monitoring system for synchronous machines based on real-time simulation

  • Author

    Han, Myungjin ; Beguin, A. ; Nicolet, C. ; Kawkabani, B.

  • Author_Institution
    Ecole Polytech. Fed. de Lausanne, Lausanne, Switzerland
  • fYear
    2014
  • fDate
    2-5 Sept. 2014
  • Firstpage
    1485
  • Lastpage
    1491
  • Abstract
    This paper presents a low power test bench of 6.25 (kVA) set up to validate a concept of monitoring system, based on real-time simulations. The bench is composed of a synchronous generator mechanically coupled to a DC motor, reproducing the dynamic behavior of a hydroelectric power plant. Running in real-time in parallel with the physical system, the simulation model of the test bench is validated by comparing the measurements and the simulation results during a transient case involving resistive load steps.
  • Keywords
    DC motors; condition monitoring; hydroelectric power stations; synchronous machines; DC motor; advanced condition monitoring system; hydroelectric power plant; real time simulation; resistive load steps; synchronous generator; synchronous machines; Computational modeling; Current measurement; Integrated circuit modeling; Load modeling; Mathematical model; Real-time systems; Voltage measurement; Condition monitoring; Real-Time simulation; Synchronous generator; Test bench;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines (ICEM), 2014 International Conference on
  • Conference_Location
    Berlin
  • Type

    conf

  • DOI
    10.1109/ICELMACH.2014.6960378
  • Filename
    6960378