DocumentCode
1582263
Title
High frequency loss evaluation in high frequency multi-winding power transformers
Author
Dhawan, Rakesh K. ; Davis, Patrick ; Lotfi, Ashraf W.
Author_Institution
Schott Corp., Wayzata, MN, USA
Issue
0
fYear
1995
Firstpage
354
Abstract
A high frequency power transformer (HFPT) with twin secondaries is generally analyzed with each primary ampere-turn being canceled by an equal contribution from each of the two secondaries. Such a methodology does not indicate worst case high frequency losses. This paper analyzes a high frequency power transformer (HFPT) with twin secondaries under a number of interleaving sequences. Each sequence is analyzed under five loading conditions. Under different conditions the primary ampere-turns are canceled by unequal contribution from each of the two secondaries. It is shown that the worst case high frequency losses occur when there is an extreme case of unbalance between the two secondaries
Keywords
finite element analysis; high-frequency transformers; power transformers; transformer windings; 1D analytical method; 2D analytical method; finite element analysis; high frequency loss evaluation; high frequency multi-winding power transformers; interleaving sequences; loading conditions; primary ampere-turn; secondary turns; unbalance analysis; Energy storage; Finite element methods; Frequency; Interleaved codes; Lakes; Magnetic fields; Power dissipation; Power transformers; Shape; Wire;
fLanguage
English
Publisher
ieee
Conference_Titel
Applied Power Electronics Conference and Exposition, 1995. APEC '95. Conference Proceedings 1995., Tenth Annual
Conference_Location
Dallas, TX
Print_ISBN
0-7803-2482-X
Type
conf
DOI
10.1109/APEC.1995.468973
Filename
468973
Link To Document