• DocumentCode
    1592200
  • Title

    Diagnostics forz-pinch on PTS facility

  • Author

    Xianbin Huang ; Siqun Zhang ; Shaotong Zhou ; Xiaodong Ren ; Hongchun Cai ; Jiakun Dan ; Shuchao Duan ; Kai Ouyang

  • Author_Institution
    Key Lab. of Pulsed Power, CAEP, Mianyang, China
  • fYear
    2013
  • Firstpage
    1
  • Lastpage
    1
  • Abstract
    Summary form only given. An extensive diagnostics with spatial and temporal resolution for Z-pinch was developed on the PTS facility at Key Labora tory of Pulsed Power, CAEP. PTS facility can generate a curr ent rising to 8-10 MA in 90 ns, which was used to drive wire array Z pinches. Diagnostics including soft X-ray power meter, DANTE, transmission grating spectrometer, time-resolved X-ray pinhole camera, optical/X-ray streak cameras, X-ray crystal spectrometer, laser differential interferometer and some experimental results are described in this paper.
  • Keywords
    X-ray spectrometers; Z pinch; diffraction gratings; light interferometers; nuclear magnetic resonance; plasma diagnostics; spatiotemporal phenomena; streak cameras; CAEP; DANTE; PTS facility; X-ray crystal spectrometer; X-ray streak camera; current 8 MA to 10 MA; current generation; laser differential interferometer; optical streak camera; soft X-ray power meter; spatial resolution; temporal resolution; time 90 ns; time-resolved X-ray pinhole camera; transmission grating spectrometer; wire array Z pinch;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Plasma Science (ICOPS), 2013 Abstracts IEEE International Conference on
  • Conference_Location
    San Francisco, CA
  • ISSN
    0730-9244
  • Type

    conf

  • DOI
    10.1109/PLASMA.2013.6634831
  • Filename
    6634831