• DocumentCode
    1592969
  • Title

    Topology optimization in the passive shim for the permanent magnet NMR

  • Author

    Yang, Liu ; Yang, Minghao ; Dong, Lanlan

  • Author_Institution
    Coll. of Eng., China Agric. Univ., Beijing, China
  • fYear
    2010
  • Firstpage
    13
  • Lastpage
    16
  • Abstract
    An improved method for allowing a NMR magnet to meet its field homogeneity requirements has been developed. Using the adjoint variable method, topology design sensitivity is derived analytically. Coupled with continuum topology sensitivity analysis, steep descent method is employed to find an optimized distribution of the shimming block of iron for the permanent magnets NMR. Different free induction decay signal data shows the effectiveness of the proposed optimal design method.
  • Keywords
    NMR spectroscopy; optimisation; permanent magnets; sensitivity analysis; shims; topology; NMR magnet; adjoint variable method; optimal design method; permanent magnet; shimming block; steep descent method; topology design sensitivity; topology optimization; NMR; Permanent magnet; Sensitivity analysis; Topology optimization;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    World Automation Congress (WAC), 2010
  • Conference_Location
    Kobe
  • ISSN
    2154-4824
  • Print_ISBN
    978-1-4244-9673-0
  • Electronic_ISBN
    2154-4824
  • Type

    conf

  • Filename
    5665553