DocumentCode :
1593954
Title :
Large generator vibration monitoring
Author :
Fortin, T. ; Duffeau, F.
Author_Institution :
Electr. de France, Paris, France
fYear :
1997
Firstpage :
155
Lastpage :
159
Abstract :
Two major generator incidents have resulted in unplanned and extensive outages in French nuclear power plants. A large action was launched to prevent this kind of incident. One part of this programme is improving on-line generator vibration monitoring. As far as the EDF Research and Development Division is concerned, the aim was to define end-winding stator vibration monitoring. Today, EDF nuclear power plants are equipped with on-line stator end-winding vibration monitoring. Previous studies, undertaken in EDF, enabled optimisation of the number and, above all, the location of sensors. The first goal of this monitoring is the protection of the machine, in order to avoid critical failure. But, the database which was created makes it possible to develop new methods, using vibration measurements, which are really interesting. So, the method described is a powerful tool to anticipate and to plan operation and maintenance actions. The on-line stator vibration monitoring is no more only a protection device but also a maintenance optimisation tool
Keywords :
stators; EDF; French nuclear power plants; generator protection; generator vibration monitoring; maintenance optimisation tool; maintenance planning; on-line generator vibration monitoring; stator end-winding vibration monitoring;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Electrical Machines and Drives, 1997 Eighth International Conference on (Conf. Publ. No. 444)
Conference_Location :
Cambridge
ISSN :
0537-9989
Print_ISBN :
0-85296-696-2
Type :
conf
DOI :
10.1049/cp:19971058
Filename :
677079
Link To Document :
بازگشت