DocumentCode
1609601
Title
Retrofitting pipelines with induction motors
Author
Finley, W.R. ; Holter, W.G.
Author_Institution
Siemens Energy & Autom. Inc., Norwood, OH, USA
fYear
1997
Firstpage
287
Lastpage
293
Abstract
This paper includes a discussion of the design considerations, testing and application of a large stiff shaft two pole motor designed for fixed or adjustable frequency drive (AFD) of pumps for a pipeline retrofit. A rotor-dynamics analysis of the rotor bearing system is presented for the as-built design and for alternate bearing designs. Test data is presented for complete shop tests with the motor and drive system. The project consisted of 22 motors plus 2 spares rated 3000 hp at 1.15 service factor and 3600 r.p.m. at 60 Hz. These motors, rated 4000 V are for use at variable speeds and torque from 23.5 to 60 Hz. A second more recent project is also briefly described in the paper consisting of 18 motors and one spare rated 4000 hp at 1.15 service factor and 3600 RPM at 60 Hz. These 4000 V motors are for use at variable speeds and torque from 24 to 66 Hz
Keywords
induction motor drives; maintenance engineering; project engineering; pumps; rotors; 23.5 to 60 Hz; 24 to 66 Hz; 3000 hp; 4000 V; 4000 hp; 60 Hz; application; design; induction motors; pipeline pump retrofitting; rotor bearing system; rotor-dynamics analysis; service factor; stiff-shaft two-pole motor; testing; Automation; Drives; Frequency; Induction motors; Pipelines; Rotors; Shafts; System testing; Torque; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Petroleum and Chemical Industry Conference, 1997. Record of Conference Papers. The Institute of Electrical and Electronics Engineers Incorporated Industry Applications Society 44th Annual
Conference_Location
Banff, Alta.
ISSN
0090-3507
Print_ISBN
0-7803-4217-8
Type
conf
DOI
10.1109/PCICON.1997.648195
Filename
648195
Link To Document