DocumentCode :
1630515
Title :
Saturation in synchronous machines due to voltage sags
Author :
Carlsson, Fredrik
Author_Institution :
Electr. Eng., R. Inst. of Technol., Stockholm, Sweden
Volume :
3
fYear :
2003
Firstpage :
1571
Abstract :
Voltage sags and voltage interruptions are huge power quality problems for many industries. Voltage sags cause, apart from eventual tripping, flux saturation, which cause large currents. This paper illustrates how the stator flux in a synchronous machine changes during voltage sags. It is shown that for some voltage sags, there will be flux saturation. Flux saturation causes both large currents and torque; these may quicken the aging of the machine. A comparison is done with a model without saturation included. This study includes only three-phase symmetrical voltage sags.
Keywords :
ageing; magnetic flux; power supply quality; stators; synchronous machines; aging; flux saturation; power quality; stator flux; synchronous machine; synchronous machines saturation; three-phase symmetrical voltage sags; tripping; voltage sags; Electrical equipment industry; Electrical products industry; Equations; Machinery production industries; Power quality; Shafts; Stators; Synchronous machines; Torque; Voltage fluctuations;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electric Machines and Drives Conference, 2003. IEMDC'03. IEEE International
Print_ISBN :
0-7803-7817-2
Type :
conf
DOI :
10.1109/IEMDC.2003.1210660
Filename :
1210660
Link To Document :
بازگشت