  • Abstract
    Whilst loading a 5kW prototype multistage axial-flux permanent magnet synchronous machine, an unbalanced load sharing characteristic between stages was revealed. This results in the dominating stage undergoing a higher temperature rise. Unequal stator currents and power factors result in a lower overall machine efficiency. The cause of this problem is investigated and future design considerations are recommended.
  • Keywords
    load (electric); machine testing; magnetic flux; permanent magnet machines; power factor; stators; synchronous machines; 5 kW; design considerations; machine efficiency reduction; multistage axial-flux permanent magnet synchronous machine; temperature rise; unbalanced load sharing characteristic; unequal power factors; unequal stator currents; Permanent magnet machines; Permanent magnets; Prototypes; Rotors; Shafts; Stacking; Stator cores; Stator windings; Temperature; Topology;