This paper presents a design solution for a high precision current-shunt monitor allowing input common-mode levels from -0.3V to 30V, independent of the supply voltage. The maximum referred to input offset voltage is ±10μV, over the entire common-mode input range. The proposed configuration has a fixed gain of 200 and exhibits a maximum gain error of 0.1%. The supply voltage can vary between 2.6V and 30V. The circuit has been designed in a 0.25μm BCD technology with a die area of only 0.8mm2.
Keywords
integrated circuit design; operational amplifiers; BCD technology; circuit design; common-mode input range; extended input common-mode voltage range; high precision current-shunt monitor design; size 0.25 mum; voltage -0.3 V to 30 V; Accuracy; Layout; Monitoring; Operational amplifiers; Rails; Resistors; Topology; auto-zero stabilized; common gate; current-shunt monitor; extended common-mode input range;