DocumentCode
1666652
Title
Maximum power point tracking technique
Author
El-Shibini, M.A. ; Rakha, H.H.
Author_Institution
Dept. of Electr. Eng., Cairo Univ., Egypt
fYear
1989
Firstpage
21
Lastpage
24
Abstract
It is noted that to overcome the problem of mismatch between solar cells and a given load, maximum power-point tracking should be used. A simple efficient maximum power-point tracking technique is developed. The connection strategy depends on a very simple criterion which is the measurement of the solar radiation level. The control strategy is based on appropriate logic that compares the signs of dP /dt and dV /dt . The proposed technique is applied to the cases of resistive load, resistive load with battery, and dynamic load
Keywords
solar cell arrays; battery; dynamic load; maximum power-point tracking; maximum power-point tracking technique; resistive load; solar cells mis-match; Circuits; Electric variables measurement; Logic; Photovoltaic cells; Photovoltaic systems; Power measurement; Signal generators; Solar power generation; Temperature; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrotechnical Conference, 1989. Proceedings. 'Integrating Research, Industry and Education in Energy and Communication Engineering', MELECON '89., Mediterranean
Conference_Location
Lisbon
Type
conf
DOI
10.1109/MELCON.1989.49971
Filename
49971
Link To Document