• DocumentCode
    166848
  • Title

    Measuring handler CDM stress provides guidance for factory static controls

  • Author

    Steinman, Arnold ; Maloney, Timothy J.

  • Author_Institution
    Electron. Workshop/Dangelmayer Assoc., Berkeley, CA, USA
  • fYear
    2014
  • fDate
    7-12 Sept. 2014
  • Firstpage
    1
  • Lastpage
    7
  • Abstract
    A handler simulator with a 50-ohm current detector creates CDM events for analysis and circuit modeling. The 50 ohms is mathematically removed to leave only air spark resistance, and the synthesized waveform, with higher peak current, is shown to relate to both CDM tester results and E-field in the factory.
  • Keywords
    electrostatic discharge; production equipment; CDM stress; CDM tester; charged device model; current detector create; electric field; factory static control guidance; handler simulator; Current measurement; Discharges (electric); Electrostatic discharges; Mathematical model; Resistance; Sparks; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Overstress/Electrostatic Discharge Symposium (EOS/ESD), 2014 36th
  • Conference_Location
    Tucson, AZ
  • ISSN
    0739-5159
  • Type

    conf

  • Filename
    6968861