DocumentCode :
1672928
Title :
Optimum Input Volt-Ampere Control of Three-Phase Induction Motors Connected to Distributed Generating Systems
Author :
Ashfaq, Haroon ; Asghar, M. S Jamil
Author_Institution :
Dept. of Electr. Eng., Aligarh Muslim Univ.
Volume :
1
fYear :
0
Firstpage :
486
Lastpage :
488
Abstract :
At light-load conditions, the power factor of a three-phase induction motor is very poor and it draws very large volt-ampere (VA) from the source. It is undesirable for a weak distributed generating system. Here voltage reduction method is employed and an optimum speed is found at which the input VA remains minimum irrespective of the load conditions. Moreover, a condition is also derived at which the input power is minimum at the optimum voltage, for every load and any induction motor. The control range is also found for which the voltage reduction method is effective for minimizing input power
Keywords :
distributed power generation; electric current control; induction motors; machine control; voltage control; distributed generating systems; three-phase induction motors; volt-ampere control; voltage reduction method; weak distributed generating system; Breakdown voltage; Control systems; Costs; Distributed power generation; Induction generators; Induction motors; Regulators; Rotors; Stators; Voltage control; Induction motors; ac regulators; distributed generation; voltage control;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics and Drives Systems, 2005. PEDS 2005. International Conference on
Conference_Location :
Kuala Lumpur
Print_ISBN :
0-7803-9296-5
Type :
conf
DOI :
10.1109/PEDS.2005.1619735
Filename :
1619735
Link To Document :
بازگشت