Title :
Partial discharge measurements on medium voltage motors
Author :
Aksyonov, Yu. ; Golubev, A. ; Muckhortov, A. ; Rodionov, V. ; Minein, V. ; Radchenko, V. ; Prokofyev, V. ; Koshel, A. ; Krupenin, N. ; Daki, N. ; Kuznezov, O.
Author_Institution :
DIACS, Moscow, Russia
fDate :
6/21/1905 12:00:00 AM
Abstract :
Results of the online insulation diagnosis of petroleum pumping station motors of medium voltage are provided. Measures taken to ensure reliable motor operation are discussed. Features of the faults that occurred in the various types of insulation systems are given. Information on the locations of partial discharges found during the offline diagnosis are also provided
Keywords :
electric motors; insulation testing; machine insulation; machine testing; partial discharge measurement; petroleum industry; pumps; electric breakdown; insulation system fault; machine insulation testing; medium voltage motors; online insulation diagnosis; partial discharge measurements; petroleum pumping; Delamination; Insulation testing; Medium voltage; Oil insulation; Partial discharge measurement; Partial discharges; Petroleum; Pulse amplifiers; Thyristors; Voltage measurement;
Conference_Titel :
Electrical Insulation Conference and Electrical Manufacturing & Coil Winding Conference, 1999. Proceedings
Conference_Location :
Cincinnati, OH
Print_ISBN :
0-7803-5757-4
DOI :
10.1109/EEIC.1999.826205