DocumentCode :
1717314
Title :
Reverberation chamber and current injection cable system study in frequency and time domains
Author :
Andriambeloson, J.A. ; Reader, H.C. ; Wiid, P.G. ; Botha, A.R.
Author_Institution :
Dept. Electr. & Electron. Eng., Univ. of Stellenbosch, Matieland, South Africa
fYear :
2012
Firstpage :
686
Lastpage :
689
Abstract :
Cable transfer impedance is investigated using time domain (TD) techniques to reduce measurement duration. Two methods have been used: the current injection and the mode-tuned reverberation chamber technique. Initial transfer impedance results on RG-58 coaxial cable show good agreement between TD and frequency domain (FD) for both setups. The gated-TD approach permits larger frequency bands to be analysed.
Keywords :
coaxial cables; reverberation chambers; time-frequency analysis; RG-58 coaxial cable; cable transfer impedance; current injection cable system study; frequency domains; gated-TD approach; initial transfer impedance; measurement duration reduction; mode-tuned reverberation chamber technique; time domains; Coaxial cables; Current measurement; Frequency domain analysis; Impedance; Oscilloscopes; Reverberation chamber;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetics in Advanced Applications (ICEAA), 2012 International Conference on
Conference_Location :
Cape Town
Print_ISBN :
978-1-4673-0333-0
Type :
conf
DOI :
10.1109/ICEAA.2012.6328715
Filename :
6328715