• DocumentCode
    1723486
  • Title

    Interaction between equipment and power line Communication: 9-95 kHz

  • Author

    Rönnberg, S.K. ; Wahlberg, M. ; Larsson, E.O.A. ; Bollen, M.H.J. ; Lundmark, C.M.

  • Author_Institution
    Skelleftea Kraft Elnat AB, Skelleftea, Sweden
  • fYear
    2009
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    This paper presents detailed measurements of currents flowing between modern electronic devices in a domestic environment. The results shown in this paper cover the frequency range 9 to 95 kHz, being the frequency band dedicated to power-line communication by network operators. Large differences exist between different devices, even when they are of the same type. It is also shown that the voltage waveform and the emission by other equipment have a significant impact on the current flowing between a device and the grid. An important conclusion from the measurements is that the high-frequency currents mainly flow between neighbouring devices.
  • Keywords
    carrier transmission on power lines; electric current measurement; electric generators; current measurement; frequency 9 kHz to 95 kHz; generator supply; power line communication; voltage waveform; Current measurement; Distortion measurement; Electronic equipment; Fluorescent lamps; Frequency; Laboratories; Performance evaluation; Power line communications; Standby generators; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    PowerTech, 2009 IEEE Bucharest
  • Conference_Location
    Bucharest
  • Print_ISBN
    978-1-4244-2234-0
  • Electronic_ISBN
    978-1-4244-2235-7
  • Type

    conf

  • DOI
    10.1109/PTC.2009.5282131
  • Filename
    5282131