• DocumentCode
    1733079
  • Title

    Destructive physical analysis results of Ni/H/sub 2/ cells cycled in LEO regime (II)

  • Author

    Lim, Hong S. ; Zelter, Gabriela R. ; Smithrick, John J. ; Hall, Stephan W.

  • Author_Institution
    Ind. Electron. Group, Hughes Aircraft Co., Torrance, CA, USA
  • fYear
    1994
  • Firstpage
    69
  • Abstract
    Summary form only given as follows. Six 48-Ah individual pressure vessel (IPV) Ni/H 2 cells containing 26 and 31% KOH electrolytes have been on a low earth orbit (LEO) cycle life test. Three cells containing 31% KOH have failed after an average of 6400 cycles while the other three with 26% KOH have cycled for an average of 19500 cycles. The authors have carried out post-cycle characterization tests and destructive physical analyses (DPA) of all cells. The DPA included visual inspections, measurements of electrode thickness, scanning electron microscopy, chemical analyses, and measurements of nickel electrode capacity in an electrolyte flooded cell. A gradual decrease of the usable cell capacity at high rate (1.4C) was the failure mode of all cells tested. Decrease of the usable capacity was due to decrease in the utilization of the active material with cycling mainly due to build-up of low rate capacity (residual capacity) and undischargeable active material. Cycle life of one of the cells (cell 5) might have been shortened prematurely due to the breakage of the cell core. Many gradual changes occurred with cycling at a rate which is independent of the KOH concentrations. Each of these individual changes are difficult to be attributed to be the direct cause of the utilization decrease. However, an involved interaction of the changes might be responsible for the decrease.<>
  • Keywords
    electrochemical electrodes; electrolytes; hydrogen; inspection; nickel; scanning electron microscope examination of materials; secondary cells; thickness measurement; KOH; KOH electrolytes; LEO regime; Ni-H/sub 2/; Ni/H/sub 2/ cells; chemical analyses; destructive physical analysis; electrode thickness measurement; electrolyte flooded cell; failure mode; individual pressure vessel cells; low Earth orbit; nickel electrode capacity measurements; post-cycle characterization tests; scanning electron microscopy; undischargeable active material; visual inspections; Aerospace electronics; Aircraft; Electrodes; Electronic equipment testing; Extraterrestrial measurements; Industrial electronics; Low earth orbit satellites; NASA; Nickel; Thickness measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Battery Conference on Applications and Advances, 1994., Proceedings of the Ninth Annual
  • Conference_Location
    Long Beach, CA, USA
  • Print_ISBN
    0-7803-1795-5
  • Type

    conf

  • DOI
    10.1109/BCAA.1994.283615
  • Filename
    283615